Removing
1. Disconnect a wire of weight from the storage battery. For more information refer to Specification.
2.
CAUTION: When removing the air filter outlet piping, check if the rubber seal on the lower air duct on the left side is dislodged. Check that the seal is properly seated on the lower piping.
Remove the air filter outlet pipe.
- Remove 2 screws.
- Release the clamp.
3. Remove the air filter assembly.
- Disconnect the electrical connector.
- Detach the air filter from the 2 bushings.
4.
NOTE: Do not proceed with further disassembly if the part is being removed only for access.
Disconnect the manifold absolute pressure sensor electrical connector (MAP).
- Remove the 2 Tox screws.
- Remove the O-ring.
Installation
1.
CAUTION: When installing the air filter outlet piping, make sure it is correctly fixed to the lower air duct to ensure a tight seal.
NOTE: When installing the air filter, make sure the dowel pins fit into the bushings.
Reinstall the elements in reverse order.