
Where orientation marks are provided on the hose and corresponding component, the marks must be aligned when the hose is fitted. Hoses must be fitted fully on to their connection points, usually a moulded form on a pipe provides a positive indicator.
Hose clips


'Quick-fit' connections are also installed to certain hoses/pipes. Inspect 'quick-fit' connections for damage, prior to connection. Replace if damaged. After engagement of 'quick-fit' connections, perform a 'tug' test to make sure connection is securely fitted.
Комментарии к этой статье