Contents: Removal ⇩ Installation ⇩
Materials
| Name | Specification |
| Silicone sealant | WSE-M4G323-A4 |
Removal
NOTE: It is shown for the left-hand drive variant, and for the right-hand drive variant it is the same.
1. Disconnect the coolant expansion tank from the radiator pipe.

2. Release the expansion tank. Unscrew the bolt.

3. Disconnect the blower fan motor electrical connector.

4. Remove the electric blower fan. Unscrew the 3 screws.
[The article is based on information from the website lrman.ru]

Installation
1. Install the components in place in the reverse order. Apply a bead of sealant to the mating surfaces of the blower motor and its housing. sealant
2. Tighten (tightening torque 10 Nm).