GENERAL INFORMATION, Precautions when working with electrical equipment.
Dismantling
1. Disconnect "negative" battery terminal.
2. Remove the 10 mounting box cover screws and remove the cover.
3. Disconnect the glow plug control unit from the junction box.
4. Disconnect the connector from the control unit.
5. Turn away a nut of fastening of a wire, disconnect a wire and remove the control block.
Assembly
1. Move the control box to its place, connect the wire and tighten the nut. Tightening torque 6 Nm.
2. Connect the connector to the unit and install the control unit in the mounting box.
3. Install the junction box cover, screw in the screws and tighten them to 2 Nm.
4. Attach "negative" battery terminal.
5. If a new glow plug control unit has been installed, reconfigure the control system using the TestBook/T4.