GENERAL INFORMATION, Precautions when working with electrical equipment.
Dismantling
1. Disconnect "negative" battery terminal.
2. Disconnect the connector from the boost pressure control solenoid valve.
3. Tag and disconnect the vacuum hoses.
4. Turn away a nut of fastening of a vacuum receiver and take a receiver aside.
5. Turn away 2 nuts of fastening of the electromagnetic valve and remove the valve from an arm.
Assembly
1. Install the solenoid valve and tighten the nuts to 10 Nm.
2. Attach vacuum hoses.
3. Connect the connector.
4. Install the vacuum reservoir and tighten the nut to 10 Nm.
5. Attach "negative" battery terminal.