Dismantling
1. Unfasten the 2 latches securing the combined flow/air temperature sensor (MAF/IAT) to the air filter cover. Disconnect the afterburner pump inlet hose (SAI) from the air filter cover.
2. Unfasten the 4 latches and remove the air filter cover.
3. Discard the air cleaner cover O-ring.
4. Remove the air filter element.
Assembly
1. Blow out the air filter housing.
2. Install the air cleaner element.
3. Install the air cleaner cover O-ring.
4. Lubricate the O-ring.
5. Replace the filter cover and fasten the latches.
6. Connect the afterburner pump hose to the air filter cover (SAI).
Comments on this article