Contents: Recommended lubricants ⇩ General technical characteristics ⇩ Tightening torque specifications ⇩
Recommended lubricants
| Name | Specification |
| Heated oxygen sensor thread | Use a heat-resistant compound to prevent seizing. |
General technical characteristics
| Name | Specification |
| Exhaust manifolds | Metal, with air gap and exhaust gas recirculation (EGR) pipe on the left manifold |
| Exhaust system | Dual stainless steel exhaust pipes with stainless steel mufflers |
| Catalytic Converters - Type/Location | Closed cascade - located in each pipe with gas passage from top to bottom with sensors before and after the neutralizer in each pipe |
Tightening torque specifications
| Name | Nm | lb-ft |
| ** HO2S | 45 | 33 |
| Catalytic Converter Mounting Clamp | 55 | 40 |
| Catalytic converter to muffler mounting nut with mounting clamp | 48 | 35 |
| Exhaust pipe | 55 | 40 |
| * Bolts securing the catalytic converter to the exhaust manifold | 22 | 16 |
* New bolts must be installed
** Apply a suitable heat-resistant anti-seize compound
The original source of the article is the website: www.lrman.ru